    Main Instructing
    Switch the modes between cool and heat; Control temperature by setting the temperature setting value and the difference value; Temperature calibration. Refrigerating control output delay protection; Alarm when temperature exceeds temperature limit or when sensor error.
    Specification and Size
    Front panel size: 75(l)×34.5(w)mm
    Sensor length: 2M (include the probe)
    Product size: 75(l)×34.5(w)×85(h)mm
    Mounting size: 71(l)×29(w)mm
    Technical parameters
    Temperature measuring range:-50℃~99℃
    Resolution:0.1℃
    Accuracy:±1℃(-50℃~70℃)
    Sensor error delay: 1 minute
    Power supply: AC110V~220V
    Power consumption:<3W
    Relay contact capacity: Cool(10A/AC250V); Heat(10A/AC250V) Sensor: NTC 10K (1pce)
    Ambient temperature:0℃~60℃
    Storage temperature: -30℃~75℃
    Relative humidity:20~85% (No condensate)
    Display instruction:
    three-digit LED +Minus digit+ Status indicator light (Status indicator light(Cool, Heat)+Set indicator (Set)
    Key instruction:
    ”S”: the key to set; “▲”: Up key;”▼”: Down key; ” ”:the key to turn on and off the power
    Indicator light status instruction
    Indicator light
    Function
    Note
    Cool indicator light
    On: refrigeration starts; Off: refrigeration stops; flash: compressor delay
    Cool, Heat indicator light can not be “on” status simultaneously
    Heat indicator light
    On: heating starts; Off: heating stops;
    Set indicator light
    On: parameter setting status
    Key operation instruction
    1.The way to check parameter:
    Under normal working status, press and release”▲ ” key once instantly, it display temperature setting value; press and release” ▼ ” key once instantly, it displays the difference value. It back to display the normal temperature display status in 2s.
    2.The way to set parameter:
    Under controller normal working status, press ”S” key for 3s or more to enter parameter modifying mode, and the ”Set” indicator light on, screen display the first menu code”F1”. Press”▲” key to avoid the interference, the sensor down-lead and power wire should be kept a distance or “▼” key to page up and page down menu item to find accordingly code, press“S” key to display the parameter set value of the current menu. press and hold “S” key, press “▲” key or “▼” key again to adjust up and down the parameter setting value of the current menu item. Press and hold both “S” key and “▲” key or “▼”key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the “  ” key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 30 seconds, system won’t save modified parameter, screen back to display normal temperature. Screen display “Er” if error appears during parameter saving, and back to normal working status 3 seconds.
    3.Restore system data
    When electrified, system will check itself, screen will display “Er” if error exit, please press any key at this time, and it restore default value and enter into normal working mode. It is advised to reset the parameter value under this condition
    Operation instruction
    Under controller normal working status, press and hold “  ”key for 3s can turn off the controller; under controller “off” status, press and hold “  ” key for 3s can turn on the controller.
    Under the controller normal working status, screen display the current temperature value; also the controller can also switch the working mode between heating and cooling.
    Controller starts refrigerating with cool indicator light on when the measuring temperature≥temperature set value+ difference value, and the refrigerating relay is connected; the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
    System starts heating when the measuring temperature value ≤the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; when the measuring temperature ≥ temperature set value , the “Heat” indicatorlight is off, and the heat relay disconnects.
    Menu instruction
    Code
    Function
    Set range
    Default
    F1
    Temperature set value
    -50℃~99℃
    10℃
    F2
    Difference set value
    1-10℃
    3℃
    F3
    Compressor delay time
    1-10 min
    3 min
    F4
    Temperature calibration value
    -10℃~10℃
    0℃
    Error description
    Alarm when sensor error: controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer, and the nixie tube display ”EE”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
    Alarm when he measuring temperature exceeds temperature measuring range: controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube display ”HH”, press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
    Safety regulations
    ★Danger
    1、Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay.
    2、Dangers:prohibit connecting the wire terminals without electricity cut-off.
    ★Waring
    1、Prohibit using the machine under the environment of over damp, high temp, strong electromagnetism interference or strong corrosion.
    ★Notice
    1、The power supply should conform to the voltage value indicated in the instruction.
    2、To avoid the interference, the sensor down-lead and power wire should be kept a distance.
    Shipping
    Feedback
    Contact us
    Return Policy
    Shipping
    Domestic
    We believe you need to get your purchases as quick as possible. As a general rule your item will be shipped within 24 hours of you purchasing it. We pack and post from Tuesday to Sunday (Mondays we are closed) but definitely get all our mail off to the post office first thing Monday morning for you. Mail gets picked up at 12pm so chances are if you buy before lunchtime your item will leave the same day.
    International
    Same as above but understand that depending on what part of the world you are from it does take a little longer to send, delivery can be from 7-15 working days. Also other factors to take into consideration are quarantine and customs regulations in your country. It is also a consideration that customs duties and GST/VAT may be payable at the buyers expense.
    Combined Postage (for items with shipping charges):
    We are more than happy to combine postage, just use the Buy it Now function in eBay (but DO NOT PAY after purchasing each item) to buy all the products you need, when you have finished request a combined invoice, we will base the shipping cost on the size, weight and your location.
    Feedback
    * When you satisfied with our product and services please leave us positive feedback.
    * If you have got the package, please confirm "
    Delivery on time
    " For us.
    * If a problem occurs, contact us immediately with any email request.
    * Just contact us using the "
    Ask the seller a question
    " link on eBay.
    Your Satisfaction is our Priority. Our goal is to make all our customers as happy as possible while shopping with us.
    Contact us
    For anything problem about product, price, shipping or order status, pleasecontact us via eBay message.Just contact us using the "
    Ask the seller a question
    " link on eBay.
    We expect positive feedback and 5 scores DSR  from you.
    Return Policy
    We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
    If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund to you after the returned item arrived at our warehouse.
    Please include your eBay ID and item number with any email requests.